DOI: 10.4244/EIJ-E-21-00006

Valve-in-valve TAVI: the new standard therapy for failing bioprosthetic valves?

Stephan Baldus1, MD; Victor Mauri1, MD

Surgical aortic valve replacement (SAVR) remains the standard of care in younger patients at low operative risk, with a clear trend towards a more liberal indication for the implantation of bioprosthetic valves even in patients younger than 65 years old. Consequently, the number of patients who will outlive the lifetime of a bioprosthesis is expected to grow. Limited durability due to structural valve deterioration remains the principal limitation of bioprosthetic aortic valve replacement. Lifetime incidences of repeat SAVR up to 45% have been reported, depending on age at first SAVR1.

Until recently, redo SAVR has been the standard of care for failing bioprostheses. However, compared to SAVR in a native valve, this procedure is linked to higher operative mortality and morbidity2. Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has been introduced as an alternative to surgery in patients unsuitable for reoperation or at particularly increased operative risk, with growing experience over recent years34. Whether TAVI, which recently evolved as the standard of care in elderly patients and those at increased operative risk, is also a valuable treatment option for patients with failing aortic valve bioprostheses still remains a matter of debate.

In this issue of EuroIntervention, Majmundar et al5 report the results of a retrospective cohort study based on a large administrative database comparing the outcomes of 6,769 patients with failed aortic bioprostheses undergoing ViV TAVI or redo SAVR. Baseline criteria were substantially different, with ViV TAVI patients being older (79 vs 65 years) and presenting with a higher comorbidity burden. Nonetheless, relevant in-hospital outcomes including mortality (1.2% vs 3.4%), bleeding (29.7% vs 67.7%), cardiorespiratory complications (9.3% vs 26.5%), and length of hospital stay were significantly lower in patients receiving ViV TAVI as compared to those undergoing repeat SAVR. These differences remained after propensity score adjustments for baseline characteristics. In contrast, ViV TAVI was associated with significantly higher rates of 30-day (16.1% vs 11.5%) and six-month (33.8% vs 24.5%) hospital readmission.

This study significantly extends previous knowledge by giving a representative insight into trends and outcomes of current clinical practice. The large sample size, based on an administrative dataset including both ViV TAVI and redo SAVR procedures, limits the risk of selection bias. Compared to a recently published analysis based on the same database but covering an earlier time period, outcomes appear to have improved, most likely reflecting growing operator experience, improved patient selection and the advent of next generation prostheses. Despite the fact that ViV TAVI patients were substantially older and sicker, mortality remained lower, which suggests that the safety of this approach as compared to redo surgery is potentially underestimated. The higher rate of hospital readmission is likely to be a result of the higher burden of comorbidities in these patients.

Regardless of these clearly impressive results, several limitations of the current analysis need to be taken into account. Since the outcomes were based on the International Classification of Diseases codes, data on predicted surgical risk, functional outcomes, or haemodynamics are lacking. For example, valvular gradients are not listed. These are a critical determinant for the long-term prognosis of patients undergoing this procedure, in particular in those of younger age and with a higher level of activity6. The small size of the initially implanted bioprosthesis, severe prosthesis-patient-mismatch and small aortic root are predictors of adverse outcome after ViV TAVI4, which – so far – can only in part be overcome with modern implantation techniques and the choice of the prosthesis. The favourable data on mortality in the ViV TAVI group probably also reflect that a number of patients with unfavourable anatomy for ViV TAVI, but a higher surgical risk, had to be treated surgically, which may have led to the higher mortality rates in the SAVR group.

To summarise, the study reaffirms the safety of ViV TAVI in selected patients with failed aortic bioprostheses and impressively supports the role of transcatheter aortic valve therapies. This study calls for prospective, randomised data to clarify whether this treatment option is indeed superior with respect to mortality and durability in this constantly growing group of patients.

Conflict of interest statement

The authors have no conficts of interest to declare in relation to the content of this editorial.

Supplementary data

To read the full content of this article, please download the PDF.


References

Volume 17 Number 15
Feb 18, 2022
Volume 17 Number 15
View full issue


Key metrics

Suggested by Cory

CLINICAL RESEARCH

10.4244/EIJV12I7A144 Sep 18, 2016
Redo TAVI: initial experience at two German centres
Schmidt T et al
free
Trending articles
151.43

State-of-the-Art

10.4244/EIJ-D-22-00776 Apr 3, 2023
Computed tomographic angiography in coronary artery disease
Serruys PW et al
free
55.9

Clinical research

10.4244/EIJ-D-22-00621 Feb 20, 2023
Long-term changes in coronary physiology after aortic valve replacement
Sabbah M et al
free
54.9

Expert review

10.4244/EIJ-D-21-01010 Jun 24, 2022
Device-related thrombus following left atrial appendage occlusion
Simard T et al
free
43.75

Clinical Research

10.4244/EIJ-D-21-01091 Aug 5, 2022
Lifetime management of patients with symptomatic severe aortic stenosis: a computed tomography simulation study
Medranda G et al
free
39.95

Clinical research

10.4244/EIJ-D-22-00558 Feb 6, 2023
Permanent pacemaker implantation and left bundle branch block with self-expanding valves – a SCOPE 2 subanalysis
Pellegrini C et al
free
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2024 Europa Group - All rights reserved