SHORT REPORT

DOI: 10.4244/EIJ-D-18-00287

Use of covered stents in the field of congenital heart diseases: the role of new players

Younes Boudjemline1,2,3*, MD, PhD

Introduction

While devices for closure of abnormal vessels or bare metal stents (BMS) for stenosis relief are commonly available, the number of covered stents (CovStents) remains scarce in the field of paediatric and adult congenital heart diseases (CHD). These stents are used as a bail-out procedure when dilatation or BMS implantation has led to vessel rupture or to exclude some abnormal connections (such as fenestration) or aneurysmal formation1,2. The most commonly used covered stent in our field is the CP Stent® (NuMED Inc., Hopkinton, NY, USA). The fragile covering implies a precautious use during ex vivo manipulations and sheath insertion. A few other CovStents coming from the field of interventional radiology have been introduced recently but their use in patients with CHD has not been reported extensively. The aim of our study is to present and describe the use of CovStents in recent practice and define the impact of new players in patients with CHD.

Materials and methods

Consecutive CHD patients receiving CovStents from 01/2016 to 06/2017 were included in the study. The study was approved by an institutional review committee. Patients and/or their parents gave informed consent. During the period, multiple stents were available: the CP Stent, and the LIFESTREAM® stent (Bard Peripheral Vascular, Inc., Tempe, AZ, USA) throughout the period, and the BeGraft stent (Bentley Innomed GmbH, Hechingen, Germany) from February to June 2017. A description of the CovStents is provided in Table 1. Procedural data were collected including indications for CovStents, number and types of stent, efficiency of the covering, the need for post-dilatation and its effect on covering, and success of the procedure. Results are expressed as mean or median value±standard deviation and range.

Results

A total of 94 stents were implanted in 77 patients (median age 1.5 years [0.1-69.7], median weight 36.8 kg [4.3-87]) including 43 CP, 38 LIFESTREAM and 13 BeGraft stents. The use of new CovStents increased with time in parallel with the decreasing use of the CP Stent. Indications for CovStents were as follows: fenestration exclusion (n=25), relief of severe stenosis/vessel occlusion (n=13), Potts creation (n=11), during pulmonary valve implantation to reduce paravalvular leak (n=10), or as a bail-out procedure for conduit rupture (n=4), for treatment of intrastent intimal proliferation (n=9), and exclusion of abnormal vascular anomalies (n=5). Thirty-eight of 51 BeGraft/LIFESTREAM stents were post-dilated using a balloon 2 to 6 mm larger than the labelled diameter. Immediate angiographic evaluation showed no extravasation and excellent function of the covering before and after post-dilatation when performed (Figure 1). At last follow-up (median 1.6 years [0.9-2.3]), no patient had failure of implanted stents requiring clinical attention or any intervention. One patient had redo catheterisation for creation of a fenestration three weeks after fenestration closure. This patient had a severe enteropathy due to a large thrombus in his total cavopulmonary connection (TCPC). His fenestration was closed to avoid stroke and peripheral emboli, knowing that he will need reopening of the fenestration after heparin infusion.

Figure 1. Recoarctation stenting using two Bentley covered stents. A) & B) Angiograms in LAO and lateral view showing a severe recoarctation of the transverse arch and an aneurysm. C) & D) Inflation of the second stent at different stages. E) & F) Aspect of the stent at full inflation (E) and after deflation (F) showing no significant recoil. G) Aspect after post-dilatation of the distal part. H) Final angiogram showing perfect apposition of the stent and exclusion of the aneurysm.

Discussion

We report our experience with the use of CovStents in recent practice. Until recently, available CovStents (CP stent) were far from ideal because of the poor quality of the covering. This explains our policy to use CovStents mainly as a bail-out in case of iatrogenic vessel damage or to treat a specific lesion that cannot be treated by a BMS. However, the arrival of new game players in that field might change our policy in the future. The superiority of the new CovStents has definitely modified our first choice of stent in situations where a covered stent is needed.

Limitations

Interventionists in the field are reluctant to use new CovStents because of recent experience with the Advanta™ V12 (Maquet, Rastatt, Germany). Secondary collapses were reported. The reasons behind this complication are unclear but were attributed to the malapposition of the stent and the important recoil. The sandwich technology used for the covering was proposed in order to explain the poor radial force of the Advanta. The LIFESTREAM stent shares the same technology whereas the covering of the BeGraft stent is similar to the CP Stent, the covering being external only and not embedded in the stent. This might explain why the recoil and radial strength of the BeGraft are comparable to or better than those of the CP Stent. The intrinsic properties of the BeGraft stent exceed those of its competitors. In addition, the BeGraft stent also offers a larger portfolio in terms of diameter and length. For these reasons, since February 2017, the BeGraft aortic stent has been used almost exclusively in situations where the CP was also a choice.

Conclusion

In conclusion, the intrinsic properties and covering of BeGraft stents are far better than those of CP Stents. Their use has increased over the years and it now represents the first-line stent used in our unit.

Impact on daily practice

The CP Stent was until recently the only available covered stent in paediatric cardiology. New CovStents have recently been introduced onto the market (LIFESTREAM and BeGraft). The quality of the covering and the intrinsic properties of the BeGraft explain the reduced use of CP Stents in our laboratory. These new CovStents can be used in daily practice in a wide range of indications.

Conflict of interest statement

The author has no conflicts of interest to declare.

Volume 14 Number 9
Oct 12, 2018
Volume 14 Number 9
View full issue


Key metrics

Suggested by Cory

EXPERT REVIEW

10.4244/EIJV12I10A210 Nov 20, 2016
Coronary covered stents
Kilic D et al
free

10.4244/EIJV14I16A278 Mar 20, 2019
Should we implant a covered stent only when there is no other solution?
Colombo A and Mangieri A
free

10.4244/EIJV10I11A210 Mar 20, 2015
Stenting the arterial duct
Witsenburg M
free

CLINICAL RESEARCH

10.4244/EIJY15M01_09 Mar 20, 2015
The VALEO® vascular stent for cardiovascular lesions in children
Ovaert C et al
free

EXPERT REVIEW

10.4244/EIJV11I6A133 Oct 20, 2015
The effectiveness of stenting of coarctation of the aorta: a systematic review
Hartman E et al
free

CLINICAL RESEARCH

10.4244/EIJ-D-18-00855 Mar 20, 2019
Very long-term outcome of coronary covered stents: a report from the SCAAR registry
Harnek J et al
free

Clinical research

10.4244/EIJ-D-18-00923 Mar 20, 2020
Percutaneous reintervention on aortic coarctation stenting
Pan M et al
free
Trending articles
152.9

Clinical research

10.4244/EIJ-D-20-01125 Oct 20, 2021
An upfront combined strategy for endovascular haemostasis in transfemoral transcatheter aortic valve implantation
Costa G et al
free
47.8

NEW INNOVATION

10.4244/EIJ-D-15-00467 Feb 20, 2018
Design and principle of operation of the HeartMate PHP (percutaneous heart pump)
Van Mieghem NM et al
free
39.1

Clinical research

10.4244/EIJ-D-22-00558 Feb 6, 2023
Permanent pacemaker implantation and left bundle branch block with self-expanding valves – a SCOPE 2 subanalysis
Pellegrini C et al
free
38.95

State-of-the-Art

10.4244/EIJ-D-23-00912 Oct 7, 2024
Optical coherence tomography to guide percutaneous coronary intervention
Almajid F et al
free
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2024 Europa Group - All rights reserved