Original Research

DOI: 10.4244/EIJ-D-24-00514

Readmissions after next-day discharge following transcatheter aortic valve implantation

Rodrigo Bagur1, MD, PhD; Michael W.A. Chu1, MD; Conrad Kabali2, MSc, PhD; Santiago Ordoñez1, MD; Ali S. Husain3, MBBCh, MSc; Sung-Han Yoon4, MD; Luis A. Palma Dallan4, MD, PhD; Abdulmajeed Alosail3, MD; Jasem Althekrallah2, MD; Mathew Valdis1, MD; Patrick Teefy1, MD; Pantelis Diamantouros1, MD; John G. Webb3, MD; Guilherme F. Attizzani4, MD, PhD

Abstract

Background: No data compare newer-generation transcatheter heart valves (THVs) in terms of next-day discharge (NDD) following transfemoral (TF) transcatheter aortic valve implantation (TAVI).

Aims: We aimed to evaluate the safety of NDD in unselected patients who received ACURATE (neo/neo2), Evolut (PRO/PRO+/FX) and the SAPIEN (3/Ultra) THVs.

Methods: This multicentre registry included patients who underwent TF-TAVI without a preprocedural permanent pacemaker implantation (PPI) and were discharged the next day without a new PPI. The primary endpoint was unplanned readmissions at 30 days. Multinomial gradient-boosted inverse probability of treatment-weighted (IPTW) propensity scores (stage 1) followed by the modified Poisson regression (stage 2) approach were used to compare the average effects of the THVs on the primary outcome.

Results: A total of 963 all-comer patients (ACURATE=264, Evolut=306, and SAPIEN=393) were included in this study. ACURATE patients were older (p<0.001) and included a greater proportion of females (p<0.001), whereas Evolut patients had a higher risk profile as assessed by the Society of Thoracic Surgeons score (p=0.01). There were no differences between the groups in terms of right or left bundle branch block (p=0.75). At 30 days, the overall readmission rate was 8%, and there were no differences in cardiac (ACURATE 4.6% vs Evolut 4.2% vs SAPIEN 3.1%; p=0.56) or non-cardiac readmissions (ACURATE 4.6% vs Evolut 3.3% vs SAPIEN 4.6%; p=0.64). Readmission for new PPI was 2.7%, 1.0% and 1.8% (p=0.32) and for heart failure (HF) was 1.5%, 2.0% and 1.3% (p=0.76) in ACURATE, Evolut and SAPIEN patients, respectively. The IPTW propensity score model followed by modified Poisson regression indicate that, using ACURATE as the reference, no significant differences were found in 30-day readmissions (relative risk [RR] 0.76, 95% confidence interval [CI]: 0.38-1.52; p=0.38 for Evolut and RR 0.74, 95% CI: 0.44-1.22; p=0.28 for SAPIEN).

Conclusions: In pacemaker-naïve patients undergoing TF-TAVI with newer-generation THVs, NDD was not associated with a negative impact on overall 30-day readmissions, cardiac or non-cardiac readmissions, readmissions for PPI or HF after discharge, or mortality, regardless of the type of THV.

Sign in to read
the full article

Forgot your password?
No account yet?
Sign up for free!

Create my pcr account

Join us for free and access thousands of articles from EuroIntervention, as well as presentations, videos, cases from PCRonline.com

Volume 20 Number 24
Dec 16, 2024
Volume 20 Number 24
View full issue


Key metrics

Suggested by Cory

Editorial

10.4244/EIJ-E-24-00056 Dec 16, 2024
Is next-day discharge after uncomplicated transcatheter aortic valve implantation the new standard of care?
Costa G and Sammartino S
free

Editorial

10.4244/EIJ-E-22-00050 Jan 23, 2023
Rocky II, Rambo II, and the ACURATE neo2
Serruys PW et al
free

CLINICAL RESEARCH

10.4244/EIJ-D-18-00168 Sep 20, 2018
Propensity-matched comparison of clinical outcomes after transaortic versus transfemoral aortic valve replacement
Chollet T et al
free
Trending articles
225.18

State-of-the-Art Review

10.4244/EIJ-D-21-00426 Dec 3, 2021
Myocardial infarction with non-obstructive coronary artery disease
Lindahl B et al
free
105.78

Expert consensus

10.4244/EIJ-E-22-00018 Dec 4, 2023
Definitions and Standardized Endpoints for Treatment of Coronary Bifurcations
Lunardi M et al
free
77.85

State-of-the-Art

10.4244/EIJ-D-23-00840 Sep 2, 2024
Aortic regurgitation: from mechanisms to management
Baumbach A et al
free
68.7

Clinical research

10.4244/EIJ-D-21-00545 Sep 20, 2022
Coronary lithotripsy for the treatment of underexpanded stents: the international; multicentre CRUNCH registry
Tovar Forero M et al
free
47.8

NEW INNOVATION

10.4244/EIJ-D-15-00467 Feb 20, 2018
Design and principle of operation of the HeartMate PHP (percutaneous heart pump)
Van Mieghem NM et al
free
43.4

Clinical research

10.4244/EIJ-D-23-00590 Dec 4, 2023
Prognostic impact of cardiac damage staging classification in each aortic stenosis subtype undergoing TAVI
Nakase M et al
free
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2024 Europa Group - All rights reserved