INTERVENTIONAL FLASHLIGHT

DOI: 10.4244/EIJ-D-17-00164

First transjugular edge-to-edge mitral valve repair with the MitraClip system

Neil P. Fam*, MD, MSc; Edwin C. Ho, MD; Naveed Ahmed, MD, DM; Jeremy Edwards, MD

An 86-year-old woman presented with heart failure and persistent NYHA IV symptoms. Her past history included atrial fibrillation and pulmonary embolism with inferior vena cava filter. Transoesophageal echocardiography (TEE) demonstrated severe mitral regurgitatiton (MR) with P2 flail segment (Panel A-Panel C, Moving image 1). Transfemoral venous catheterisation was impossible due to venous occlusion. After Heart Team discussion, the patient’s surgical risk was deemed prohibitive and transjugular MitraClip® (Abbott Vascular, Santa Clara, CA, USA) implantation was planned.

Transseptal puncture was performed via the right internal jugular vein using the SupraCross™ system (Baylis, Montreal, Canada) (Panel D, Panel E, Moving image 2, Moving image 3). A mid-posterior septal position was selected, 4.2 cm above the mitral annulus. The MitraClip guide catheter was introduced clockwise with 180 degree rotation of the + knob for septal crossing (Panel F). The clip was inserted into the guide with a 90 degree counterclockwise rotation. Without straddling, the clip was navigated to the mitral valve using the + and P knobs (Panel G, Moving image 4). After deploying two clips, there was trace MR, with a mean gradient of 2 mmHg (Panel H-Panel J, Moving image 5). There were no complications and the patient’s condition improved, allowing discharge. Repeat echocardiography demonstrated sustained MR reduction.

In this first report, we demonstrate the feasibility of the transjugular approach for MitraClip implantation. The transjugular approach provides a more direct route to the mitral valve, and has been described for mitral valvuloplasty1 and mitral valve-in-valve replacement2. Other alternative access options for MitraClip implantation include direct right atrial puncture3 or a pulmonary venous approach via a right mini-thoracotomy4. In our case, we used a novel transseptal system that employs a steerable sheath and radiofrequency wire. Using a modified steering technique, we implanted two clips with sustained MR reduction.

When planning transjugular edge-to-edge mitral repair, several points should be considered. 1) The transseptal puncture should be superior and posterior for an optimal trajectory to the mitral valve, especially given the tendency of the sheath to move inferiorly. 2) The left atrium should be large enough to allow safe guide catheter steering. 3) Excessive guide manipulation should be avoided to prevent septal trauma. Larger studies of transjugular access for mitral edge-to-edge repair are required to confirm efficacy and safety compared to the transfemoral approach. Given the more direct route to the mitral valve, the transjugular approach may have applications for other transcatheter mitral repair or replacement devices.

Conflict of interest statement

The authors have no conflicts of interest to declare.

Supplementary data

Moving image 1. Preprocedural TEE demonstrating severe MR.

Moving image 2. Intraprocedural TEE of septal tenting with the SupraCross system.

Moving image 3. Fluoroscopy of transseptal puncture with the SupraCross system.

Moving image 4. Intraprocedural 3D TEE of the clip prior to grasping.

Moving image 5. Post-procedural TEE showing trace MR.

Supplementary data

To read the full content of this article, please download the PDF.

Preprocedural TEE demonstrating severe MR.

Intraprocedural TEE of septal tenting with the SupraCross system.

Fluoroscopy of transseptal puncture with the SupraCross system.

Intraprocedural 3D TEE of the clip prior to grasping.

Post-procedural TEE showing trace MR.

Volume 13 Number 3
Jun 20, 2017
Volume 13 Number 3
View full issue


Key metrics

On the same subject

EXPERT REVIEW

10.4244/EIJ-D-17-00505 Sep 24, 2017
Mitral valve: repair/clips/cinching/chordae
Vahanian A et al
free

Image – Interventional flashlight

10.4244/EIJ-D-23-00596 Nov 17, 2023
Electrosurgical laceration and stabilisation of three clip devices (ELASTA-Clip) to enable transcatheter mitral valve implantation
Curio J et al

10.4244/EIJV11SWA10 Sep 17, 2015
Transcatheter mitral valve repair: a brief review
Barbanti M et al
free

MITRAL VALVE INTERVENTIONS

10.4244/EIJV12SYA14 Sep 18, 2016
The MitraClip system: strategies for optimal patient selection and optimised results
Grasso C and Ince H
free

SPECIAL REPORT

10.4244/EIJV11I13A296 Apr 20, 2016
First transfemoral percutaneous edge-to-edge repair of the tricuspid valve using the MitraClip system
Wengenmayer T et al
free

INTERVENTIONAL FLASHLIGHT

10.4244/EIJ-D-17-00693 Nov 20, 2017
Transcatheter edge-to-edge repair of lead-associated tricuspid regurgitation
Fam N et al
free

10.4244/EIJV15I7A103 Sep 20, 2019
Mitral valve regurgitation: a plea for transcatheter mitral valve replacement
Modine T et al
free
Trending articles
338.03

State-of-the-Art Review

10.4244/EIJ-D-21-00904 Apr 1, 2022
Antiplatelet therapy after percutaneous coronary intervention
Angiolillo D et al
free
284.93

State-of-the-Art Review

10.4244/EIJ-D-21-00695 Nov 19, 2021
Transcatheter treatment for tricuspid valve disease
Praz F et al
free
226.03

State-of-the-Art Review

10.4244/EIJ-D-21-00426 Dec 3, 2021
Myocardial infarction with non-obstructive coronary artery disease
Lindahl B et al
free
209.5

State-of-the-Art Review

10.4244/EIJ-D-21-01034 Jun 3, 2022
Management of in-stent restenosis
Alfonso F et al
free
168.4

Expert review

10.4244/EIJ-D-21-00690 May 15, 2022
Crush techniques for percutaneous coronary intervention of bifurcation lesions
Moroni F et al
free
150.28

State-of-the-Art

10.4244/EIJ-D-22-00776 Apr 3, 2023
Computed tomographic angiography in coronary artery disease
Serruys PW et al
free
118

Translational research

10.4244/EIJ-D-22-00718 Jun 5, 2023
Preclinical evaluation of the degradation kinetics of third-generation resorbable magnesium scaffolds
Seguchi M et al
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 6.2
2022 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2023)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2024 Europa Group - All rights reserved