This case report demonstrates the potential for contrast agent-free preprocedural planning (Figure 1A-C) and transcatheter aortic valve implantation (TAVI; Figure 1D-H) of a Direct Flow Medical® (DFM) transcatheter aortic valve (Direct Flow Medical, Santa Rosa, CA, USA), a device without a metallic frame, in an 84-year-old patient with renal failure and a severe aortic valve stenosis. Avoiding any application of contrast agent, and therefore its related complications, might extend even further the indication for TAVI implantation in such high-risk patients. This approach might currently be limited to certain anatomies and special clinical situations until larger studies confirm the strategy.

Figure 1. Pre- and intraprocedural imaging. Using non-contrast 3D FLASH MRA and no-contrast CT (A), the distance to the right/left coronary ostium was measured perpendicular to the annular plane. B) The cross-sectional area was assessed by means of planimetry, and (C) an optimal fluoroscopic angulation for the DFM implantation was assessed with all three leaflets in line. Pigtail catheters were placed in the NCC (#) and RCC (*) to draw an imaginary line for identification of the landing zone for the ventricular DFM ring (D). Positioning (E) and final fluoroscopic result (F) of the DFM implantation with an optimal position. TEE confirms optimal position of the DFM valve with only trace paravalvular AR (G & H).

Conflict of interest statement

J. Reinöhl is a proctor for Direct Flow Medical. F. De Marco and A. Latib are consultants for Direct Flow Medical. The other authors have no conflicts of interest to declare.



Key metrics

Suggested by Cory

10.4244/EIJV8I5A82 Sep 28, 2012
Computed tomography to improve TAVI outcomes
Debonnaire P et al
free

AORTIC VALVE INTERVENTIONS

10.4244/EIJV12SYA6 Sep 18, 2016
TAVI with current CE-marked devices: strategies for optimal sizing and valve delivery
van Gils L et al
free

Image – Interventional flashlight

10.4244/EIJ-D-20-00426 Sep 18, 2020
Technical considerations for repeat transcatheter aortic valve implantation in a failing Direct Flow Medical transcatheter heart valve
Yap J et al
free

Image – Interventional flashlight

10.4244/EIJ-D-19-00690 Aug 28, 2020
Transcatheter aortic valve implantation after transcatheter mitral valve implantation
Kuhn E et al
free

Image – Interventional flashlight

10.4244/EIJ-D-22-00385 Jan 23, 2023
Double chimney stenting without contrast during transcatheter aortic valve-in-valve implantation
Armario X et al
free

Short report

10.4244/EIJ-D-19-01094 Jun 12, 2020
TAVR-in-TAVR and coronary access: importance of preprocedural planning
Tarantini G et al
free
Trending articles
310.93

State-of-the-Art Review

10.4244/EIJ-D-21-00695 Nov 19, 2021
Transcatheter treatment for tricuspid valve disease
Praz F et al
free
92.2

State-of-the-Art Review

10.4244/EIJ-D-20-01296 Aug 27, 2021
Management of cardiogenic shock
Thiele H et al
free
76.25

State-of-the-Art

10.4244/EIJ-D-23-00840 Sep 2, 2024
Aortic regurgitation: from mechanisms to management
Baumbach A et al
free
56.65

Clinical research

10.4244/EIJ-D-20-01155 Oct 20, 2021
A deep learning algorithm for detecting acute myocardial infarction
Liu W et al
free
35

Original Research

10.4244/EIJ-D-25-00331 May 21, 2025
One-month dual antiplatelet therapy followed by prasugrel monotherapy at a reduced dose: the 4D-ACS randomised trial
Jang Y et al
open access
26

Expert Review

10.4244/EIJ-D-24-00535 May 5, 2025
Catheter-based techniques for pulmonary embolism treatment
Costa F et al
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 9.5
2024 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2025)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2025 Europa Group - All rights reserved