IMAGE IN CARDIOLOGY

DOI: 10.4244/EIJV12I8A164

Closure of a coronary artery: coronary sinus fistula

Sudhakar George1*, MD, MBBChir, MRCP; Joseph DeGiovanni2, MD, FRCP, FRCPCH; Ian J. McCafferty2, Bsc, MBBS, MRCP, FRCR; Patrick Calvert1,3, PhD, FACC

A 61-year-old woman presented with angina and breathlessness. Coronary angiography showed a huge fistula connecting the left coronary artery to the coronary sinus and draining into the right atrium. We first attempted to close the fistula in 2014 with an 18 mm AMPLATZER™ Muscular Ventricular Septal Defect Occluder (St. Jude Medical, St. Paul, MN, USA). This reduced flow through the fistula but was not successful in closing it. The patient’s symptoms persisted and imaging demonstrated inducible myocardial ischaemia (coronary steal) anteriorly. We initially attempted to close the fistula using 13×60 cm coils. Despite deploying 780 cm of coils, a residual shunt remained. This was successfully closed by injecting ethyl-vinyl alcohol copolymer (a liquid agent that solidifies on contact with blood) into the nest of coils. At clinic review her symptoms were improved (Moving image 1-Moving image 4).

Conflict of interest statement

The authors have no conflicts of interest to declare.

Supplementary data

Moving image 1. Left coronary artery to coronary sinus fistula.

Moving image 2. Fistula with AMPLATZER closure device.

Moving image 3. Fistula with AMPLATZER device and coils.

Moving image 4. Closure of fistula with ethyl-vinyl alcohol copolymer.

Supplementary data

To read the full content of this article, please download the PDF.

Left coronary artery to coronary sinus fistula.

Fistula with AMPLATZER closure device.

Fistula with AMPLATZER device and coils.

Closure of fistula with ethyl-vinyl alcohol copolymer.

Volume 12 Number 8
Oct 10, 2016
Volume 12 Number 8
View full issue


Key metrics

On the same subject

IMAGE IN CARDIOLOGY

10.4244/EIJV12I8A165 Oct 10, 2016
Percutaneous closure of an iatrogenic aortocoronary venous fistula after coronary bypass graft surgery
Sandhu K et al
free

10.4244/EIJV12SXA6 May 16, 2016
Coronary-cameral fistulas: indications and methods for closure
Carminati M et al
free

CLINICAL RESEARCH

10.4244/EIJ-D-17-00632 Apr 6, 2018
Combined use of coils and Onyx for transcatheter closure of coronary artery fistulae
Li P et al
free

Image – Interventional flashlight

10.4244/EIJ-D-19-00649 Oct 9, 2020
Fistula between the right pulmonary artery and left atrium in a newborn: management and successful interventional treatment
Michalak K et al
free

Image – Interventional flashlight

10.4244/EIJ-D-19-00198 Jun 12, 2020
Percutaneous closure of atrial fistula after ascending aortic aneurysm surgery using cardiac fusion imaging
Cruz-González I et al
free
Trending articles
211.55

State-of-the-Art Review

10.4244/EIJ-D-21-01034 Jun 3, 2022
Management of in-stent restenosis
Alfonso F et al
free
173.13

Focus article

10.4244/EIJY19M08_01 Jan 17, 2020
EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion – an update
Glikson M et al
free
168.95

Translational research

10.4244/EIJ-D-21-00824 May 15, 2022
Bench test and in vivo evaluation of longitudinal stent deformation during proximal optimisation
Toth GG et al
free
150.93

State-of-the-Art

10.4244/EIJ-D-22-00776 Apr 3, 2023
Computed tomographic angiography in coronary artery disease
Serruys PW et al
free
76.65

State-of-the-Art

10.4244/EIJ-D-23-00840 Sep 2, 2024
Aortic regurgitation: from mechanisms to management
Baumbach A et al
free
55.9

Clinical research

10.4244/EIJ-D-22-00621 Feb 20, 2023
Long-term changes in coronary physiology after aortic valve replacement
Sabbah M et al
free
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2024 Europa Group - All rights reserved